The Effectiveness of Leucodepleted (In Line) and Leucodepleted (Bedsite) In Reducing Leukocytes and Their Effect on Hemoglobin (Hb) and Red Blood Cell (RBC)

Authors

  • Maulana Baihakhi Master of Biomedical Science Study Program, Faculty of Medicine, Prima University of Indonesia, Medan, Indonesia.
  • William Leslie Master of Biomedical Science Study Program, Faculty of Medicine, Prima University of Indonesia, Medan, Indonesia.
  • Silvia Fransisca Master of Biomedical Science Study Program, Faculty of Medicine, Prima University of Indonesia, Medan, Indonesia.

DOI:

https://doi.org/10.51601/ijhp.v3i3.175

Keywords:

Blood Transfusion, Blood Donors, Leukodepleted, Hemoglobin Red Blood Cell.

Abstract

Blood transfusion currently plays an important medical role in methods of reducing the number of leukocytes in component products, including reducing the number of leukocytes before storage (pre-storage leucodepletion) and reducing the number of leukocytes after storage (post storage leucodepletion). The purpose of this study was to determine whether there was a comparison of hemolysis events and hematocrit quality in leucodepleted (In Line) and leucodepleted (Bedsite) clinical transfusions at the Blood Transfusion Unit at the Indonesian Red Cross in Medan City. This study was an analytic study with a cross-sectional design of 58 people who were divided into two groups, namely the group with leucodepleted in line and the group with leucodepleted bedsite, inclusion and exclusion criteria. The results showed that the incidence of hemolysis after leucodepleted (in line) was 0% and leucodepleted (bedsite) was 0.02%, where the standard percentage of blood hemolysis was <0.8%, the occurrence of hemolysis after the production process of the two products was very small. While the hematocrit before and after leucodepleted decreased by 35.91% in leucodepleted (in line) and 33.33% in leucodepleted (bedsite). Comparison of leucodepleted (In Line) and leucodepleted (Bedsite) hemolysis events was also found. Where the incidence of leucodepleted (in line) hemolysis is not found, so the leucodepleted (in line) blood component has good quality.

References

Bakta, I. M. (2006). Hematologi Klinik Ringkas. Jakarta: Penerbit Buku Kedokteran EGC.

Klein H. (2005), Mollison’s blood transfusion in clinical medicine 11th edition. United Kingdom: Blackwell Publishing.

Aru S. (2014). Ilmu Penyakit Dalam: Anemia Hemolitik akibat Transfusi. Jakarta: Interna Publishing.

Savage WJ, et.al. (2011). Allergic transfusion reactions to platelets are associated more with recipient and donor factors than with product attributes. The Journal Off AABB Transfusion. 51(1) :1716-1722. https://doi.org/10.1111/j.1537-2995.2010.03009.x

Weinstein R. (2016). Red Blood Cell Transfusion: A Pocket Guide for the Clinician. American Society of Hematology.

Akbar TI. 2014. Kualitas dan Kejadian hemolisis Packed Red Cell (PRC) Washed Erythrocyte dan Leukodepleted (In-Line) dalam Transfusi Klinis. Journal Indon Med Assoc. 64 (10): 451-455.

Kumar H, et.al. (2006). Leucodepletion and Blood Product. Medical Journal Armed Frces India. 62(2):174-177.

Srihartati. (2014). Perbedaan Penurunan Jumlah Leukosit dan Sitokin pada packed-Red Cell dengan Metode Buffy-Coat Depleted dan Modifikasi Bed-Side Leucocyte Filtration. Journal indon Med Assoc. 64 (10): 447-450.

Kemenkes RI. (2016). Profil Kesehatan Indonesia tahun 2015. Jakarta.

Waterburry L. (2001). Buku Saku Hematologi Edisi 3. Jakarta: EGC.

Vassalo R. (2013). A Compendium of Transfusion Practice Guidelines Second Edition. American Red Cross.

Saragih P. (2019). Pengaruh Waktu Simpan PRC Terhadap Perubahan Hemoglobin, Hematokrit, dan Plasma Glukosa di RSUP H. Adam Malik Medan. Program Magister Kedokteran Klinik Spesialis Patologi Klinik Fakultas Kedokteran Universitas Sumatera Utara.

Horne M. (2001). Keseimbangan Cairan, Elektrolit Dan Asam Basa. Edisi 2. Jakarta: EGC

Speicher C. (2006). Pemilihan Uji Laboratorium yang Efektif. Jakarta: EGC

Samuel O. (2002). Red blood cell hemolysis during processing. Transfusion Med. 16: 46-60.

Thelma AP. Emanuela C. (2016). A Comparative Study of the Effect of Leukoreduction and Pre-Storage Leukodepletion on Red Blood Cells during Storage. Frontiers in Molecular Biosciences. 3 (13): 1-9.

Mustafa I, et. Al. (2016). Time Dependent Assessment of Morphological Changes: Leukodepleted Packed Red Blood Cells Stored in SAGM. Biomed Research International. 1-7.

European Committe (Partial Agreement) on Blood Transfusion (CD-P-TS). (2010) In: EDQM Allee Kastner editor. Guide To Preparation, Use and Quality Assurance of Blood Components. 16th Ed. Council of Europe; p. 249-262.

Downloads

Published

2022-12-16

How to Cite

Baihakhi, M. ., Leslie, W. ., & Fransisca, S. . (2022). The Effectiveness of Leucodepleted (In Line) and Leucodepleted (Bedsite) In Reducing Leukocytes and Their Effect on Hemoglobin (Hb) and Red Blood Cell (RBC) . International Journal of Health and Pharmaceutical (IJHP), 3(2), 372–379. https://doi.org/10.51601/ijhp.v3i3.175

Issue

Section

Articles